ConfigMgr 2012 SP1 with MDT 2012 Update 1, UDI Task Sequence and Bitlocker Error 6767

Redmond, we have a problem.  The “Client Task Sequence” template when used with Configuration Manager 2012 SP1 does not work too well when UDI is enabled and we want to Bitlocker our devices.

When we are performing a User Driven Installation, the MDT 2012 Update 1 template makes use of the ConfigMgr “Pre-provision Bitlocker” step, which adequately pre-provisions Bitlocker on the Operating System drive on a ‘used space only’ basis.  This is a good thing.   Later on in the Task Sequence we have an MDT specific step that uses the ZTIBde.wsf script which SHOULD configure and enable the protectors – but you may find that this will fail, resulting in an exitcode of 6767.  Tracing this error in the ZTIBde.wsf script takes us into a failure of the function that enables the Bitlocker protectors.  So what is going wrong?

Let us first understand that the ZTIBde.wsf was designed for MDT deployments primarily – with added ConfigMgr integration as an afterthought.  The ZTIBde.wsf script ON ITS OWN is capable of pre-provisioning Bitlocker in Windows PE AND ALSO, later (in the OS phase) configuring and enabling the protectors.  It’s a great little script.  In the MDT Client Task Sequence template however, the ZTIBde.wsf script is not used within the Windows PE phase to Pre-provision Bitlocker and instead the in-built ConfigMgr function is used.  The ConfigMgr function will pre-provision Bitlocker, however it does not then configure the appropriate variable that the ZTIBde.wsf Pre-provisioning function would and this is needed and consumed later by the ZTIBde.wsf script when it comes to Enabling the Bitlocker Protectors in the OS Phase.

The ZTIBde.wsf script has a section which checks if Bitlocker is enabled on the drive (IsBDE = TRUE) and also if the drive has NOT been pre-provisioned earlier (IsBDEPreProvisioned <> TRUE).  This test is used to accommodate the refresh scenario when the existing suspended protectors of a Bitlocker drive can simply be turned back on without having to configure any.  In the absence of the IsBDEPreProvisioned variable (or if it doesn’t equal TRUE) then this section of code will cause the script to skip over the configuration of any required protectors (specified in the UDI wizard) and simply try to enable any existing protectors, of which there are none – resulting in the error 6767 spat out by the EnableProtectors function.

So what do we need to do about this?  Well you could amend the script – but that wouldn’t be supported by Microsoft and your modifications could well be wiped out by any future revision (which may or may not address its shortcomings.  There are a few (non-exhaustive) alternatives that I could propose;

  1. If you are using the UDI Wizard AND you want the Bitlocker options to come through from it, then you should replace the “Pre-provision Bitlocker” step in the task sequence that uses the ConfigMgr function with the ZTIBde.wsf script – the very same script used later on to “Enable Bitlocker”.  This keeps the Pre-provisioning process and the Enable Bitlocker process solely in the MDT camp.  However, if you want the Recovery Key to be backed up to Active Directory then you will need to use a script afterwards to do that, or implement MBAM.
  2. If you are using the UDI Wizard AND are removing the Bitlocker configuration page but still want Bitlocker enabling then replace the “Enable Bitlocker” step in the task sequence with the ConfigMgr function – as you can specify the protectors used and also escrow the Recovery Key to Active Directory automatically.
  3. If you are NOT using the UDI Wizard but want to implement Bitlocker in your Task Sequence, then stick with the ConfigMgr step for pre-provisioning Bitlocker and replace the ZTIBde.wsf method for Enabling Bitlocker with the ConfigMgr function – for the same reasons as above.  In this scenario, you would need to ensure that your partitioning layout is suitable for Bitlocker.

Have fun with that!

Andy

Advertisements

ZTIMoveStateStore.wsf does not move the StateStore folder during Refresh

When ConfigMgr 2012 is integrated with MDT 2012, the Client Task Sequence template includes a step that uses ZTIMoveStateStore.wsf to move the StateStore folder to WINDOWS\TEMP in the event of success or failure, however this script has not been updated to cater for the new location of the StateStore and when it runs it will simply not find the StateStore in the expected location and exit without any error.  This isn’t too much of a problem until you attempt a second refresh of a system -which will result in the Task Sequence failing to store the user state.

To rectify this, create a backup copy of the ZTIMoveStateStore.wsf script within the MDT Toolkit Files package and then open the original for editing.  You will be looking for any references to “oUtility.LocalRootPath” and replace these with “oUtility.StatePath” and remove the additional path.  There are 6 (SIX) lines to which this amendment needs to be made;

– 1 –

If oFSO.FolderExists(oUtility.LocalRootPath & "\StateStore") Then

becomes

If oFSO.FolderExists(oUtility.StatePath) Then

– 2 –

oLogging.CreateEntry "Moving " & oUtility.LocalRootPath & "\StateStore" & " to " & sArchiveDir & "\StateStore", LogTypeInfo

becomes

oLogging.CreateEntry "Moving " & oUtility.StatePath & " to " & sArchiveDir & "\StateStore", LogTypeInfo

– 3 –

oFSO.MoveFolder oUtility.LocalRootPath & "\StateStore", sArchiveDir & "\StateStore"

becomes

oFSO.MoveFolder oUtility.StatePath, sArchiveDir & "\StateStore"

– 4 –

oLogging.CreateEntry "Error moving " & oUtility.LocalRootPath & "\StateStore" & " to " & sArchiveDir & "\StateStore: " & Err.Description & " (" & Err.Number & ").  Trying to copy", LogTypeWarning

becomes

oLogging.CreateEntry "Error moving " & oUtility.StatePath & " to " & sArchiveDir & "\StateStore: " & Err.Description & " (" & Err.Number & ").  Trying to copy", LogTypeWarning

– 5 –

OFSO.CopyFolder oUtility.LocalRootPath & "\StateStore", sArchiveDir & "\StateStore"

becomes

OFSO.CopyFolder oUtility.StatePath, sArchiveDir & "\StateStore"

– 6 –

oLogging.CreateEntry "Error Copying " & oUtility.LocalRootPath & "\StateStore" & " to " & sArchiveDir & "\StateStore: " & Err.Description & " (" & Err.Number & ").  Trying to copy", LogTypeWarning

becomes

oLogging.CreateEntry "Error Copying " & oUtility.StatePath & " to " & sArchiveDir & "\StateStore: " & Err.Description & " (" & Err.Number & ").  Trying to copy", LogTypeWarning

 

This has worked great for me.